thomson_scattering
¶
Thomson scattering diagnostic
Maximum occurrences (MDS+ backend only): 3
New in version 3.0.4: lifecycle status alpha
Changed in version 4.1.0.
ids_propertiesstructure¶
See common IDS structure reference: ids_properties
.
midplanestructure¶Choice of midplane definition for the mapping of measurements […]
Choice of midplane definition for the mapping of measurements on an equilibrium. Indicate the IMAS URI of the used equilibrium IDS in the ids_properties/provenance section.
This is an identifier. See midplane_identifier
for the available options.
New in version >3.32.1.
channel(i1)AoS¶Set of channels (lines-of-sight)
Set of channels (lines-of-sight)
Maximum occurrences (MDS+ backend only): 150
1 |
|
channel(i1)/nameSTR_0D¶Short string identifier (unique for a given device)
Short string identifier (unique for a given device)
channel(i1)/descriptionSTR_0D¶Description, e.g. […]
Description, e.g. “channel viewing the upper divertor”
New in version >3.
channel(i1)/line_of_sightstructure¶Description of the line of sight of the channel, given by 2 points
Description of the line of sight of the channel, given by 2 points
New in version >3.41.0.
channel(i1)/line_of_sight/first_pointstructure¶Position of the first point
Position of the first point
channel(i1)/polychromator_indexINT_0D¶Index of the polychromator used by this channel (refers to the […]
Index of the polychromator used by this channel (refers to the ../../polychromator array)
New in version >3.41.0.
channel(i1)/scattering_angle(:) ⇹radFLT_1D¶Angle formed by the laser beam wave vector and the line of sight, […]
Angle formed by the laser beam wave vector and the line of sight, counted clockwise when projected in the poloidal plane
1 |
New in version >3.41.0.
channel(i1)/scattering_length ⇹mFLT_0D¶Length of the light scattering volume (full width) along the […]
Length of the light scattering volume (full width) along the laser beam path, for this line of sight (i.e. length of the intersection between the laser beam and the viewing cone). This is a time average value in case of different lasers fired at different times
New in version >4.0.0.
channel(i1)/solid_angleINT_0D¶Solid angle of the line of sight
Solid angle of the line of sight
New in version >3.41.0.
channel(i1)/positionstructure¶Average position of the measurements (intersection between laser […]
Average position of the measurements (intersection between laser beam and line of sight)
channel(i1)/delta_positionstructure¶Incremental variation of the position of the measurements, due […]
Incremental variation of the position of the measurements, due to e.g. different lasers not intersecting the line of sight at the same position. The actual position is then the static position + delta_position
channel(i1)/position_per_laserstructure¶Position of the intersection between each laser beam and this […]
Position of the intersection between each laser beam and this line of sight
1 |
channel(i1)/position_per_laser/phi(:) ⇹radFLT_1D¶Toroidal angle (oriented counter-clockwise when viewing from […]
Toroidal angle (oriented counter-clockwise when viewing from above)
1 |
channel(i1)/distance_separatrix_midplanemstructure¶Distance between the measurement position and the separatrix, […]
Distance between the measurement position and the separatrix, mapped along flux surfaces to the outboard midplane, in the major radius direction. Positive value means the measurement is outside of the separatrix.
New in version >3.32.1.
channel(i1)/t_eeVstructure¶Electron temperature
Electron temperature
channel(i1)/t_e/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
channel(i1)/t_e/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
channel(i1)/n_em^-3structure¶Electron density
Electron density
channel(i1)/n_e/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
channel(i1)/n_e/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
channel(i1)/gaussian_fit(:,:) ⇹mixedFLT_2D¶Amplitude of the gaussian fit of the measured signal in each […]
Amplitude of the gaussian fit of the measured signal in each energy band, used to estimate the electron temperature
1 |
|
2 |
New in version >3.41.0.
laser(i1)AoS¶Set of probing lasers
Set of probing lasers
Maximum occurrences (MDS+ backend only): 3
1 |
|
New in version >3.41.0.
laser(i1)/energy_inJstructure¶Energy of the laser pulse measured just before entering the vacuum […]
Energy of the laser pulse measured just before entering the vacuum vessel
laser(i1)/energy_outJstructure¶Energy of the laser pulse measured after crossing the plasma
Energy of the laser pulse measured after crossing the plasma
laser(i1)/start_pointstructure¶Position of the laser start point
Position of the laser start point
polychromator(i1)AoS¶Set of polychromators
Set of polychromators
Maximum occurrences (MDS+ backend only): 40
1 |
|
New in version >3.41.0.
polychromator(i1)/wavelength_band(i2)AoS¶Set of wavelength bands in which photons are counted by the polychromator
Set of wavelength bands in which photons are counted by the polychromator
Maximum occurrences (MDS+ backend only): 8
1 |
|
polychromator(i1)/wavelength_band(i2)/wavelength_lower ⇹mFLT_0D¶Lower bound of the detector wavelength range
Lower bound of the detector wavelength range
polychromator(i1)/wavelength_band(i2)/wavelength_upper ⇹mFLT_0D¶Upper bound of the detector wavelength range
Upper bound of the detector wavelength range
polychromator(i1)/wavelength_band(i2)/wavelengths(:) ⇹mFLT_1D¶Array of wavelength values
Array of wavelength values
1 |
|
polychromator(i1)/calibration_absolute(:) ⇹1FLT_1D¶Factor to be multiplied by the spectral calibration to obtain […]
Factor to be multiplied by the spectral calibration to obtain the instrument function (fraction of signal received on each energy channel when a photon of relevant energy enters the optical system)
1 |
polychromator(i1)/calibration_absolute_dateSTR_0D¶Date at which the absolute calibration was carried out
Date at which the absolute calibration was carried out