langmuir_probes

Langmuir probes

  • Maximum occurrences (MDS+ backend only): 3

New in version 3.22.0: lifecycle status alpha

Changed in version 3.39.0.

ids_propertiesstructure

See common IDS structure reference: ids_properties.

midplanestructureChoice of midplane definition for the mapping of measurements […]

Choice of midplane definition for the mapping of measurements on an equilibrium (use the lowest index number if more than one value is relevant). Indicate the IMAS URI of the used equilibrium IDS in the ids_properties/provenance structure.

This is an identifier. See midplane_identifier for the available options.

New in version >3.32.1.

midplane/nameSTR_0DShort string identifier

Short string identifier

midplane/indexINT_0DInteger identifier (enumeration index within a list). […]

Integer identifier (enumeration index within a list). Private identifier values must be indicated by a negative index.

midplane/descriptionSTR_0DVerbose description

Verbose description

embedded(i1)AoSSet of embedded (in a plasma facing component) probes

Set of embedded (in a plasma facing component) probes

  • Maximum occurrences (MDS+ backend only): 100

Coordinate

1

1...N

embedded(i1)/nameSTR_0DShort string identifier (unique for a given device)

Short string identifier (unique for a given device)

embedded(i1)/descriptionSTR_0DDescription, e.g. […]

Description, e.g. “channel viewing the upper divertor”

New in version >3.

embedded(i1)/positionstructurePosition of the measurements

Position of the measurements

embedded(i1)/position/rmFLT_0DMajor radius

Major radius

embedded(i1)/position/phiradFLT_0DToroidal angle (oriented counter-clockwise when viewing from […]

Toroidal angle (oriented counter-clockwise when viewing from above)

embedded(i1)/position/zmFLT_0DHeight

Height

embedded(i1)/surface_aream^2FLT_0DArea of the probe surface exposed to the plasma (use when assuming […]

Area of the probe surface exposed to the plasma (use when assuming constant effective collection area)

embedded(i1)/surface_area_effectivem^2structureEffective collection area of the probe surface, varying with […]

Effective collection area of the probe surface, varying with time due to e.g. changes in the magnetic field line incidence angle

embedded(i1)/surface_area_effective/data(:)m^2FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/surface_area_effective/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/surface_area_effective/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/v_floatingVstructureFloating potential

Floating potential

Changed in version 3.30.0: Renamed from potential_floating

embedded(i1)/v_floating/data(:)VFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/v_floating/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/v_floating/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/v_floating_sigmaVstructureStandard deviation of the floating potential, corresponding to […]

Standard deviation of the floating potential, corresponding to the fluctuations of the quantity over time

New in version >3.32.1.

embedded(i1)/v_floating_sigma/data(:)VFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/v_floating_sigma/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/v_floating_sigma/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/v_plasmaVstructurePlasma potential

Plasma potential

Changed in version 3.30.0: Renamed from potential_plasma

embedded(i1)/v_plasma/data(:)VFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/v_plasma/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/v_plasma/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/t_eeVstructureElectron temperature

Electron temperature

embedded(i1)/t_e/data(:)eVFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/t_e/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/t_e/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/n_em^-3structureElectron density

Electron density

embedded(i1)/n_e/data(:)m^-3FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/n_e/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/n_e/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/t_ieVstructureIon temperature

Ion temperature

embedded(i1)/t_i/data(:)eVFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/t_i/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/t_i/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/j_i_parallelA.m^-2structureIon parallel current density at the probe position

Ion parallel current density at the probe position

Changed in version 3.30.0: Renamed from j_ion_parallel

embedded(i1)/j_i_parallel/data(:)A.m^-2FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_parallel/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_parallel/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/j_i_parallel_sigmaA.m^-2structureStandard deviation of ion parallel current density at the probe […]

Standard deviation of ion parallel current density at the probe position

New in version >3.32.1.

embedded(i1)/j_i_parallel_sigma/data(:)A.m^-2FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_parallel_sigma/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_parallel_sigma/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/ion_saturation_currentAstructureIon saturation current measured by the probe

Ion saturation current measured by the probe

Changed in version 3.30.0: Renamed from saturation_current_ion

embedded(i1)/ion_saturation_current/data(:)AFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/ion_saturation_current/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/ion_saturation_current/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/j_i_saturationA.m^-2structureIon saturation current density

Ion saturation current density

New in version >3.32.1.

embedded(i1)/j_i_saturation/data(:)A.m^-2FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/j_i_saturation_skew1structureSkew of the ion saturation current density

Skew of the ion saturation current density

New in version >3.32.1.

embedded(i1)/j_i_saturation_skew/data(:)1FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation_skew/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation_skew/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/j_i_saturation_kurtosis1structurePearson kurtosis of the ion saturation current density

Pearson kurtosis of the ion saturation current density

New in version >3.32.1.

embedded(i1)/j_i_saturation_kurtosis/data(:)1FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation_kurtosis/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation_kurtosis/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/j_i_saturation_sigmaA.m^-2structureStandard deviation of the ion saturation current density, corresponding […]

Standard deviation of the ion saturation current density, corresponding to the fluctuations of the quantity over time

New in version >3.32.1.

embedded(i1)/j_i_saturation_sigma/data(:)A.m^-2FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation_sigma/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/j_i_saturation_sigma/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/heat_flux_parallelW.m^-2structureParallel heat flux at the probe position

Parallel heat flux at the probe position

embedded(i1)/heat_flux_parallel/data(:)W.m^-2FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/heat_flux_parallel/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/heat_flux_parallel/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/fluencem^-2structurePositive charge fluence normal to an ideal axisymmetric surface […]

Positive charge fluence normal to an ideal axisymmetric surface of the divertor (assuming no shaping), estimated at the probe location.

New in version >3.38.1.

embedded(i1)/fluence/data(:)m^-2FLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/fluence/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/fluence/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/b_field_angleradstructureIncident angle of the magnetic field with respect to PFC surface

Incident angle of the magnetic field with respect to PFC surface

embedded(i1)/b_field_angle/data(:)radFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/b_field_angle/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/b_field_angle/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/distance_separatrix_midplanemstructureDistance between the measurement position and the separatrix, […]

Distance between the measurement position and the separatrix, mapped along flux surfaces to the outboard midplane, in the major radius direction. Positive value means the measurement is outside of the separatrix.

Changed in version 3.33.0: Renamed from distance_separatrix

New in version >3.32.1.

embedded(i1)/distance_separatrix_midplane/data(:)mFLT_1DData

Data

Coordinate

1

embedded(i1)/time

embedded(i1)/distance_separatrix_midplane/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/time

embedded(i1)/distance_separatrix_midplane/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/multi_temperature_fits(i2)AoSSet of temperatures describing the electron and ion distribution […]

Set of temperatures describing the electron and ion distribution functions in case of multi-temperature fits

  • Maximum occurrences (MDS+ backend only): 2

Coordinate

1

1...N

embedded(i1)/multi_temperature_fits(i2)/t_eeVstructureElectron temperature

Electron temperature

embedded(i1)/multi_temperature_fits(i2)/t_e/data(:)eVFLT_1DData

Data

Coordinate

1

embedded(i1)/multi_temperature_fits(i2)/time

embedded(i1)/multi_temperature_fits(i2)/t_e/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/multi_temperature_fits(i2)/time

embedded(i1)/multi_temperature_fits(i2)/t_e/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/multi_temperature_fits(i2)/t_ieVstructureIon temperature

Ion temperature

embedded(i1)/multi_temperature_fits(i2)/t_i/data(:)eVFLT_1DData

Data

Coordinate

1

embedded(i1)/multi_temperature_fits(i2)/time

embedded(i1)/multi_temperature_fits(i2)/t_i/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

embedded(i1)/multi_temperature_fits(i2)/time

embedded(i1)/multi_temperature_fits(i2)/t_i/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

embedded(i1)/multi_temperature_fits(i2)/time(:)sFLT_1DTimebase for the dynamic nodes of this probe located at this […]

Timebase for the dynamic nodes of this probe located at this level of the IDS structure

Coordinate

1

1...N

embedded(i1)/time(:)sFLT_1DTimebase for the dynamic nodes of this probe located at this […]

Timebase for the dynamic nodes of this probe located at this level of the IDS structure

Coordinate

1

1...N

reciprocating(i1)AoSSet of reciprocating probes

Set of reciprocating probes

  • Maximum occurrences (MDS+ backend only): 100

Coordinate

1

1...N

reciprocating(i1)/nameSTR_0DShort string identifier (unique for a given device)

Short string identifier (unique for a given device)

reciprocating(i1)/descriptionSTR_0DDescription, e.g. […]

Description, e.g. “channel viewing the upper divertor”

New in version >3.

reciprocating(i1)/surface_area(:)m^2FLT_1DArea of the surface exposed to the plasma of each collector (constant […]

Area of the surface exposed to the plasma of each collector (constant assuming negligible dependence on e.g. the magnetic field line angle)

Coordinate

1

reciprocating(i1)/plunge(itime)/collector

reciprocating(i1)/plunge(itime)AoSSet of plunges of this probe during the pulse, each plunge being […]

Set of plunges of this probe during the pulse, each plunge being recorded as a time slice from the Access Layer point of view. The time child node corresponds to the time of maximum penetration of the probe during a given plunge. The dynamics of physical quantities within the plunge are described via the time_within_plunge vector.

Coordinate

1

reciprocating(i1)/plunge(itime)/time

reciprocating(i1)/plunge(itime)/position_averagestructureAverage position of the measurements derived from multiple collectors

Average position of the measurements derived from multiple collectors

reciprocating(i1)/plunge(itime)/position_average/r(:)mFLT_1DMajor radius

Major radius

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/position_average/z(:)mFLT_1DHeight

Height

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/position_average/phi(:)radFLT_1DToroidal angle

Toroidal angle

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/position_average/validity_timed(:)INT_1DIndicator of the validity of the position data for each time […]

Indicator of the validity of the position data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/position_average/validityINT_0DIndicator of the validity of the position data for the whole […]

Indicator of the validity of the position data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)AoSSet of probe collectors including measurements specific to each […]

Set of probe collectors including measurements specific to each collector. The number of collectors (size of this array of structure) is assumed to remain constant for all plunges

Coordinate

1

1...N

reciprocating(i1)/plunge(itime)/collector(i2)/positionstructurePosition of the collector

Position of the collector

reciprocating(i1)/plunge(itime)/collector(i2)/position/r(:)mFLT_1DMajor radius

Major radius

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/position/z(:)mFLT_1DHeight

Height

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/position/phi(:)radFLT_1DToroidal angle

Toroidal angle

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/position/validity_timed(:)INT_1DIndicator of the validity of the position data for each time […]

Indicator of the validity of the position data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/position/validityINT_0DIndicator of the validity of the position data for the whole […]

Indicator of the validity of the position data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/v_floatingVstructureFloating potential

Floating potential

reciprocating(i1)/plunge(itime)/collector(i2)/v_floating/data(:)VFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/v_floating/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/v_floating/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/v_floating_sigmaVstructureStandard deviation of the floating potential, corresponding to […]

Standard deviation of the floating potential, corresponding to the fluctuations of the quantity over time

New in version >3.32.1.

reciprocating(i1)/plunge(itime)/collector(i2)/v_floating_sigma/data(:)VFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/v_floating_sigma/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/v_floating_sigma/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/t_eeVstructureElectron temperature

Electron temperature

reciprocating(i1)/plunge(itime)/collector(i2)/t_e/data(:)eVFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/t_e/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/t_e/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/t_ieVstructureIon temperature

Ion temperature

reciprocating(i1)/plunge(itime)/collector(i2)/t_i/data(:)eVFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/t_i/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/t_i/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_parallelA.m^-2structureIon parallel current density at the probe position

Ion parallel current density at the probe position

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_parallel/data(:)A.m^-2FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_parallel/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_parallel/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/ion_saturation_currentAstructureIon saturation current measured by the probe

Ion saturation current measured by the probe

reciprocating(i1)/plunge(itime)/collector(i2)/ion_saturation_current/data(:)AFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/ion_saturation_current/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/ion_saturation_current/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_saturationA.m^-2structureIon saturation current density

Ion saturation current density

New in version >3.32.1.

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_saturation/data(:)A.m^-2FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_saturation/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_saturation/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_skew1structureSkew of the ion saturation current density

Skew of the ion saturation current density

New in version >3.32.1.

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_skew/data(:)1FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_skew/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_skew/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_kurtosis1structurePearson kurtosis of the ion saturation current density

Pearson kurtosis of the ion saturation current density

New in version >3.32.1.

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_kurtosis/data(:)1FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_kurtosis/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_kurtosis/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_sigmaA.m^-2structureStandard deviation of the ion saturation current density, corresponding […]

Standard deviation of the ion saturation current density, corresponding to the fluctuations of the quantity over time

New in version >3.32.1.

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_sigma/data(:)A.m^-2FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_sigma/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/j_i_sigma/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/collector(i2)/heat_flux_parallelW.m^-2structureParallel heat flux at the probe position

Parallel heat flux at the probe position

reciprocating(i1)/plunge(itime)/collector(i2)/heat_flux_parallel/data(:)W.m^-2FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/heat_flux_parallel/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/collector(i2)/heat_flux_parallel/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/v_plasmaVstructurePlasma potential

Plasma potential

Changed in version 3.30.0: Renamed from potential_plasma

reciprocating(i1)/plunge(itime)/v_plasma/data(:)VFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/v_plasma/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/v_plasma/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/t_e_averageeVstructureElectron temperature (upstream to downstream average)

Electron temperature (upstream to downstream average)

reciprocating(i1)/plunge(itime)/t_e_average/data(:)eVFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/t_e_average/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/t_e_average/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/t_i_averageeVstructureIon temperature (upstream to downstream average)

Ion temperature (upstream to downstream average)

reciprocating(i1)/plunge(itime)/t_i_average/data(:)eVFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/t_i_average/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/t_i_average/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/n_em^-3structureElectron density

Electron density

reciprocating(i1)/plunge(itime)/n_e/data(:)m^-3FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/n_e/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/n_e/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/b_field_angleradstructureIncident angle of the magnetic field with respect to PFC surface

Incident angle of the magnetic field with respect to PFC surface

reciprocating(i1)/plunge(itime)/b_field_angle/data(:)radFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/b_field_angle/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/b_field_angle/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/distance_separatrix_midplanemstructureDistance between the measurement position and the separatrix, […]

Distance between the measurement position and the separatrix, mapped along flux surfaces to the outboard midplane, in the major radius direction. Positive value means the measurement is outside of the separatrix.

Changed in version 3.33.0: Renamed from distance_separatrix

New in version >3.32.1.

reciprocating(i1)/plunge(itime)/distance_separatrix_midplane/data(:)mFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/distance_separatrix_midplane/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/distance_separatrix_midplane/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/distance_x_point_zmstructureDistance in the z direction of the measurement position to the […]

Distance in the z direction of the measurement position to the closest X-point (Zmeasurement-Zx_point)

New in version >3.32.1.

reciprocating(i1)/plunge(itime)/distance_x_point_z/data(:)mFLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/distance_x_point_z/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/distance_x_point_z/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/mach_number_parallel1structureParallel Mach number

Parallel Mach number

reciprocating(i1)/plunge(itime)/mach_number_parallel/data(:)1FLT_1DData

Data

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/mach_number_parallel/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

reciprocating(i1)/plunge(itime)/time_within_plunge

reciprocating(i1)/plunge(itime)/mach_number_parallel/validityINT_0DIndicator of the validity of the data for the whole plunge. […]

Indicator of the validity of the data for the whole plunge. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

reciprocating(i1)/plunge(itime)/time_within_plunge(:)sFLT_1DTime vector for describing the dynamics within the plunge

Time vector for describing the dynamics within the plunge

Coordinate

1

1...N

reciprocating(i1)/plunge(itime)/timesFLT_0DTime of maximum penetration of the probe during a given plunge

Time of maximum penetration of the probe during a given plunge

latencysFLT_0DUpper bound of the delay between physical information received […]

Upper bound of the delay between physical information received by the detector and data available on the real-time (RT) network.

New in version >3.32.1.

codestructure

See common IDS structure reference: code.

time(:)sFLT_1DGeneric time

Generic time

Coordinate

1

1...N