calorimetry
¶
Calometry measurements on various tokamak subsystems
Maximum occurrences (MDS+ backend only): 2
New in version 3.23.4: lifecycle status alpha
Changed in version 3.33.0.
ids_propertiesstructure¶
See common IDS structure reference: ids_properties
.
group(i1)AoS¶Set of groups of components on which calorimetry measurements […]
Set of groups of components on which calorimetry measurements are carried out (grouped by tokamak subsystems or localization on the machine)
Maximum occurrences (MDS+ backend only): 25
1 |
|
group(i1)/nameSTR_0D¶Short string identifier (unique for a given device)
Short string identifier (unique for a given device)
group(i1)/descriptionSTR_0D¶Description, e.g. […]
Description, e.g. “channel viewing the upper divertor”
New in version >3.
group(i1)/component(i2)AoS¶Set of components on which calorimetry measurements are carried […]
Set of components on which calorimetry measurements are carried out
Maximum occurrences (MDS+ backend only): 40
1 |
|
group(i1)/component(i2)/nameSTR_0D¶Short string identifier (unique for a given device)
Short string identifier (unique for a given device)
group(i1)/component(i2)/descriptionSTR_0D¶Description, e.g. […]
Description, e.g. “channel viewing the upper divertor”
New in version >3.
group(i1)/component(i2)/powerWstructure¶Power extracted from the component
Power extracted from the component
group(i1)/component(i2)/power/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
group(i1)/component(i2)/power/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
group(i1)/component(i2)/energy_cumulatedJstructure¶Energy extracted from the component since the start of the pulse
Energy extracted from the component since the start of the pulse
group(i1)/component(i2)/energy_cumulated/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
group(i1)/component(i2)/energy_cumulated/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
group(i1)/component(i2)/energy_totalJstructure¶Energy extracted from the component on the whole plasma discharge, […]
Energy extracted from the component on the whole plasma discharge, including the return to thermal equilibrium of the component in the post-pulse phase
group(i1)/component(i2)/energy_total/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
group(i1)/component(i2)/temperature_inKstructure¶Temperature of the coolant when entering the component
Temperature of the coolant when entering the component
group(i1)/component(i2)/temperature_in/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
group(i1)/component(i2)/temperature_in/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
group(i1)/component(i2)/temperature_outKstructure¶Temperature of the coolant when exiting the component
Temperature of the coolant when exiting the component
group(i1)/component(i2)/temperature_out/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
group(i1)/component(i2)/temperature_out/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
group(i1)/component(i2)/mass_flowkg.s^-1structure¶Mass flow of the coolant going through the component
Mass flow of the coolant going through the component
group(i1)/component(i2)/mass_flow/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
group(i1)/component(i2)/mass_flow/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
group(i1)/component(i2)/transit_timesstructure¶Transit time for the coolant to go from the input to the output […]
Transit time for the coolant to go from the input to the output of the component
group(i1)/component(i2)/transit_time/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
group(i1)/component(i2)/transit_time/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
cooling_loop(i1)AoS¶Set of cooling loops
Set of cooling loops
Maximum occurrences (MDS+ backend only): 8
1 |
|
cooling_loop(i1)/nameSTR_0D¶Short string identifier (unique for a given device)
Short string identifier (unique for a given device)
cooling_loop(i1)/descriptionSTR_0D¶Description, e.g. […]
Description, e.g. “channel viewing the upper divertor”
New in version >3.
cooling_loop(i1)/temperature_inKstructure¶Temperature of the coolant when entering the loop
Temperature of the coolant when entering the loop
cooling_loop(i1)/temperature_in/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
cooling_loop(i1)/temperature_in/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
cooling_loop(i1)/temperature_outKstructure¶Temperature of the coolant when exiting the loop
Temperature of the coolant when exiting the loop
cooling_loop(i1)/temperature_out/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
cooling_loop(i1)/temperature_out/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
cooling_loop(i1)/mass_flowkg.s^-1structure¶Mass flow of the coolant going through the loop
Mass flow of the coolant going through the loop
cooling_loop(i1)/mass_flow/validity_timed(:)INT_1D¶Indicator of the validity of the data for each time slice. […]
Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)
1 |
cooling_loop(i1)/mass_flow/validityINT_0D¶Indicator of the validity of the data for the whole acquisition […]
Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)