calorimetry

Calometry measurements on various tokamak subsystems

  • Maximum occurrences (MDS+ backend only): 2

New in version 3.23.4: lifecycle status alpha

Changed in version 3.33.0.

ids_propertiesstructure

See common IDS structure reference: ids_properties.

group(i1)AoSSet of groups of components on which calorimetry measurements […]

Set of groups of components on which calorimetry measurements are carried out (grouped by tokamak subsystems or localization on the machine)

  • Maximum occurrences (MDS+ backend only): 25

Coordinate

1

1...N

group(i1)/nameSTR_0DShort string identifier (unique for a given device)

Short string identifier (unique for a given device)

group(i1)/descriptionSTR_0DDescription, e.g. […]

Description, e.g. “channel viewing the upper divertor”

New in version >3.

group(i1)/component(i2)AoSSet of components on which calorimetry measurements are carried […]

Set of components on which calorimetry measurements are carried out

  • Maximum occurrences (MDS+ backend only): 40

Coordinate

1

1...N

group(i1)/component(i2)/nameSTR_0DShort string identifier (unique for a given device)

Short string identifier (unique for a given device)

group(i1)/component(i2)/descriptionSTR_0DDescription, e.g. […]

Description, e.g. “channel viewing the upper divertor”

New in version >3.

group(i1)/component(i2)/powerWstructurePower extracted from the component

Power extracted from the component

group(i1)/component(i2)/power/data(:)WFLT_1DData

Data

Coordinate

1

group(i1)/component(i2)/power/time

group(i1)/component(i2)/power/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

group(i1)/component(i2)/power/time

group(i1)/component(i2)/power/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

group(i1)/component(i2)/power/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

group(i1)/component(i2)/energy_cumulatedJstructureEnergy extracted from the component since the start of the pulse

Energy extracted from the component since the start of the pulse

group(i1)/component(i2)/energy_cumulated/data(:)JFLT_1DData

Data

Coordinate

1

group(i1)/component(i2)/energy_cumulated/time

group(i1)/component(i2)/energy_cumulated/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

group(i1)/component(i2)/energy_cumulated/time

group(i1)/component(i2)/energy_cumulated/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

group(i1)/component(i2)/energy_cumulated/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

group(i1)/component(i2)/energy_totalJstructureEnergy extracted from the component on the whole plasma discharge, […]

Energy extracted from the component on the whole plasma discharge, including the return to thermal equilibrium of the component in the post-pulse phase

group(i1)/component(i2)/energy_total/dataJFLT_0DData

Data

group(i1)/component(i2)/energy_total/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

group(i1)/component(i2)/temperature_inKstructureTemperature of the coolant when entering the component

Temperature of the coolant when entering the component

group(i1)/component(i2)/temperature_in/data(:)KFLT_1DData

Data

Coordinate

1

group(i1)/component(i2)/temperature_in/time

group(i1)/component(i2)/temperature_in/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

group(i1)/component(i2)/temperature_in/time

group(i1)/component(i2)/temperature_in/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

group(i1)/component(i2)/temperature_in/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

group(i1)/component(i2)/temperature_outKstructureTemperature of the coolant when exiting the component

Temperature of the coolant when exiting the component

group(i1)/component(i2)/temperature_out/data(:)KFLT_1DData

Data

Coordinate

1

group(i1)/component(i2)/temperature_out/time

group(i1)/component(i2)/temperature_out/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

group(i1)/component(i2)/temperature_out/time

group(i1)/component(i2)/temperature_out/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

group(i1)/component(i2)/temperature_out/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

group(i1)/component(i2)/mass_flowkg.s^-1structureMass flow of the coolant going through the component

Mass flow of the coolant going through the component

group(i1)/component(i2)/mass_flow/data(:)kg.s^-1FLT_1DData

Data

Coordinate

1

group(i1)/component(i2)/mass_flow/time

group(i1)/component(i2)/mass_flow/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

group(i1)/component(i2)/mass_flow/time

group(i1)/component(i2)/mass_flow/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

group(i1)/component(i2)/mass_flow/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

group(i1)/component(i2)/transit_timesstructureTransit time for the coolant to go from the input to the output […]

Transit time for the coolant to go from the input to the output of the component

group(i1)/component(i2)/transit_time/data(:)sFLT_1DData

Data

Coordinate

1

group(i1)/component(i2)/transit_time/time

group(i1)/component(i2)/transit_time/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

group(i1)/component(i2)/transit_time/time

group(i1)/component(i2)/transit_time/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

group(i1)/component(i2)/transit_time/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

cooling_loop(i1)AoSSet of cooling loops

Set of cooling loops

  • Maximum occurrences (MDS+ backend only): 8

Coordinate

1

1...N

cooling_loop(i1)/nameSTR_0DShort string identifier (unique for a given device)

Short string identifier (unique for a given device)

cooling_loop(i1)/descriptionSTR_0DDescription, e.g. […]

Description, e.g. “channel viewing the upper divertor”

New in version >3.

cooling_loop(i1)/temperature_inKstructureTemperature of the coolant when entering the loop

Temperature of the coolant when entering the loop

cooling_loop(i1)/temperature_in/data(:)KFLT_1DData

Data

Coordinate

1

cooling_loop(i1)/temperature_in/time

cooling_loop(i1)/temperature_in/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

cooling_loop(i1)/temperature_in/time

cooling_loop(i1)/temperature_in/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

cooling_loop(i1)/temperature_in/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

cooling_loop(i1)/temperature_outKstructureTemperature of the coolant when exiting the loop

Temperature of the coolant when exiting the loop

cooling_loop(i1)/temperature_out/data(:)KFLT_1DData

Data

Coordinate

1

cooling_loop(i1)/temperature_out/time

cooling_loop(i1)/temperature_out/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

cooling_loop(i1)/temperature_out/time

cooling_loop(i1)/temperature_out/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

cooling_loop(i1)/temperature_out/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

cooling_loop(i1)/mass_flowkg.s^-1structureMass flow of the coolant going through the loop

Mass flow of the coolant going through the loop

cooling_loop(i1)/mass_flow/data(:)kg.s^-1FLT_1DData

Data

Coordinate

1

cooling_loop(i1)/mass_flow/time

cooling_loop(i1)/mass_flow/validity_timed(:)INT_1DIndicator of the validity of the data for each time slice. […]

Indicator of the validity of the data for each time slice. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

Coordinate

1

cooling_loop(i1)/mass_flow/time

cooling_loop(i1)/mass_flow/validityINT_0DIndicator of the validity of the data for the whole acquisition […]

Indicator of the validity of the data for the whole acquisition period. 0: valid from automated processing, 1: valid and certified by the diagnostic RO; - 1 means problem identified in the data processing (request verification by the diagnostic RO), -2: invalid data, should not be used (values lower than -2 have a code-specific meaning detailing the origin of their invalidity)

cooling_loop(i1)/mass_flow/time(:)sFLT_1DTime

Time

Coordinate

1

1...N

latencysFLT_0DUpper bound of the delay between physical information received […]

Upper bound of the delay between physical information received by the detector and data available on the real-time (RT) network.

New in version >3.32.1.

codestructure

See common IDS structure reference: code.

time(:)sFLT_1DGeneric time

Generic time

Coordinate

1

1...N